The CO2SINK boreholes for geological CO2 -storage testing

Prevedel, B., Wohlgemuth, L., Legarth, B., Henninges, J., Schutt, H., Schmidt-Hattenberger, C., Norden, B., Foerster, A. and Hurter, S. (2009). The CO2SINK boreholes for geological CO2 -storage testing. In: 9th International Conference on Greenhouse Gas Control Technologies, Washington, DC, United States, (2087-2094). 16-20 November 2008. doi:10.1016/j.egypro.2009.01.272


Author Prevedel, B.
Wohlgemuth, L.
Legarth, B.
Henninges, J.
Schutt, H.
Schmidt-Hattenberger, C.
Norden, B.
Foerster, A.
Hurter, S.
Title of paper The CO2SINK boreholes for geological CO2 -storage testing
Formatted title
The CO2SINK boreholes for geological CO2 -storage testing
Conference name 9th International Conference on Greenhouse Gas Control Technologies
Conference location Washington, DC, United States
Conference dates 16-20 November 2008
Journal name Energy Procedia   Check publisher's open access policy
Place of Publication Amsterdam, Netherlands
Publisher Elsevier
Publication Year 2009
Year available 2009
Sub-type Fully published paper
DOI 10.1016/j.egypro.2009.01.272
Open Access Status DOI
ISSN 1876-6102
Volume 1
Issue 1
Start page 2087
End page 2094
Total pages 8
Language eng
Formatted Abstract/Summary
This paper reports the well design, drilling and completion operation as well as the coring technique applied in the CO2SINK project. Three boreholes, one injection well and two observation wells have been drilled to a total depth of about 800 m. 200 m of recovered 6" core material has been real-time analysed in a research field lab. The wells have been completed as "smart" wells, containing a variety of permanently installed down-hole sensors for the continuous monitoring of the CO2 in the reservoir. All wells were cased with stainless final casings equipped with pre-perforated sand filters in the reservoir zone and wired on the outside with fiber-optical and multi-conductor copper cables. The reservoir casing section is externally coated with a fiber-glass-resin wrap for electrical insulation.
Keyword Completion
Coring
Drilling
DTS
ERT
Filter screens
Geophysical monitoring
Mud loss
Q-Index Code C1
Q-Index Status Provisional Code
Institutional Status Non-UQ

Document type: Conference Paper
Sub-type: Greenhouse Gas Control Technologies 9
Collection: School of Earth and Environmental Sciences
 
Versions
Version Filter Type
Citation counts: TR Web of Science Citation Count  Cited 37 times in Thomson Reuters Web of Science Article | Citations
Scopus Citation Count Cited 50 times in Scopus Article | Citations
Google Scholar Search Google Scholar
Created: Fri, 26 May 2017, 01:00:21 EST by System User on behalf of Learning and Research Services (UQ Library)