Automated and optimal detection of 3D articular cartilage using undecimated wavelets in MRI

Aarya, Isshaa and Jiang, Danchi (2015) Automated and optimal detection of 3D articular cartilage using undecimated wavelets in MRI. Signal Image and Video Processing, 9 305-314. doi:10.1007/s11760-015-0825-x


Author Aarya, Isshaa
Jiang, Danchi
Title Automated and optimal detection of 3D articular cartilage using undecimated wavelets in MRI
Journal name Signal Image and Video Processing   Check publisher's open access policy
ISSN 1863-1711
1863-1703
Publication date 2015-12-01
Year available 2015
Sub-type Article (original research)
DOI 10.1007/s11760-015-0825-x
Open Access Status Not yet assessed
Volume 9
Start page 305
End page 314
Total pages 10
Place of publication London, United Kingdom
Publisher Springer U K
Language eng
Formatted abstract
Articular cartilage is a thin and curvilinear structure whose image may get corrupted with noise during acquisition process. Image segmentation of this structure depends on expertise of an operator. In this paper, we propose an automated cartilage detection technique using 3D histogram and wavelet multiscale singularity analysis. 3D undecimated wavelet transform is implemented on MRI volume to obtain wavelet coefficients, which are used to determine an adaptive threshold for a given local resolution and a global threshold value. Local threshold helps to segment foreground cartilage edge details and is obtained using maximum likelihood estimate of the 3D histogram for a selected confidence level of intensity histogram. A global threshold is used to optimize coefficients using wavelet multiresolution singularity. The final wavelet coefficients are used to obtain a 3D model of cartilage tissue. The proposed method has been tested and validated using MRI and phantom datasets of articular cartilage. Quantitative analysis has been performed using mean square error (MSE), signal-to-noise ratio (SNR) and volumetric estimation of the datasets for different confidence and noise levels. The proposed method displays reduction in MSE for both denoised and noisy MRI volumes at different standard deviations of noise with overall improvement in SNR.
Keyword 3D histogram
Adaptive threshold
Articular cartilage detection
Multiresolution analysis
Rician distribution
Undecimated wavelet transform
Q-Index Code C1
Q-Index Status Provisional Code
Institutional Status Non-UQ

Document type: Journal Article
Sub-type: Article (original research)
Collection: Centre for Advanced Imaging Publications
 
Versions
Version Filter Type
Citation counts: TR Web of Science Citation Count  Cited 0 times in Thomson Reuters Web of Science Article
Scopus Citation Count Cited 0 times in Scopus Article
Google Scholar Search Google Scholar
Created: Thu, 06 Apr 2017, 01:00:31 EST by Web Cron on behalf of Learning and Research Services (UQ Library)