Hybrid clutter rejection technique for improved microwave head imaging

Zamani, Ali and Abbosh, Amin (2015) Hybrid clutter rejection technique for improved microwave head imaging. IEEE Transactions on Antennas and Propagation, 63 11: 4921-4931. doi:10.1109/TAP.2015.2479238


Author Zamani, Ali
Abbosh, Amin
Title Hybrid clutter rejection technique for improved microwave head imaging
Journal name IEEE Transactions on Antennas and Propagation   Check publisher's open access policy
ISSN 0018-926X
1558-2221
Publication date 2015-11-01
Year available 2015
Sub-type Article (original research)
DOI 10.1109/TAP.2015.2479238
Open Access Status Not Open Access
Volume 63
Issue 11
Start page 4921
End page 4931
Total pages 11
Place of publication Piscataway, NJ, United States
Publisher Institute of Electrical and Electronics Engineers
Language eng
Abstract The accuracy of microwave head imaging is adversely affected by strong clutters that can completely mask the target response. To that end, different clutter removal techniques are modified for multistatic frequency-based imaging. It is shown that some deficiencies of those methods in time domain, such as time overlapping, can be alleviated when they are modified for use in frequency domain. Based on the explored performance of different methods in the frequency domain, a hybrid technique, which combines the benefits of average subtraction and entropy-based filtering methods, is proposed. In this method, the average value of the multistatic scattered signals is subtracted from them at each frequency sample to remove late-stage clutters, whereas an entropy-based method is applied to mitigate early-stage strong clutters. The proposed technique is verified in realistic environments using simulations and experiments. The utilized system for verification is 1.1-3.2 GHz frequency-domain multistatic with an eight-element antenna array, and compact microwave transceiver. The simulations are performed on MRI-derived head model, whereas the experiments are done on realistic artificial head phantom. The obtained results from different locations and sizes of emulated brain injuries confirm the effectiveness of the proposed method in producing high quality images of the head after mitigating the clutter.
Keyword Brain imaging
Clutter rejection
Microwave imaging
Multi-static radar imaging
Q-Index Code C1
Q-Index Status Confirmed Code
Institutional Status UQ

Document type: Journal Article
Sub-type: Article (original research)
Collections: Official 2016 Collection
School of Information Technology and Electrical Engineering Publications
 
Versions
Version Filter Type
Citation counts: TR Web of Science Citation Count  Cited 8 times in Thomson Reuters Web of Science Article | Citations
Scopus Citation Count Cited 11 times in Scopus Article | Citations
Google Scholar Search Google Scholar
Created: Tue, 24 Nov 2015, 10:30:49 EST by System User on behalf of Scholarly Communication and Digitisation Service