A Simple and Reliable Ethylene Gassing System for Plant Studies

Poole, MC and Joyce, DC (1993) A Simple and Reliable Ethylene Gassing System for Plant Studies. Australian Journal of Experimental Agriculture, 33 4: 507-510. doi:10.1071/EA9930507


Author Poole, MC
Joyce, DC
Title A Simple and Reliable Ethylene Gassing System for Plant Studies
Journal name Australian Journal of Experimental Agriculture   Check publisher's open access policy
ISSN 0816-1089
Publication date 1993-01-01
Year available 1993
Sub-type Article (original research)
DOI 10.1071/EA9930507
Open Access Status Not yet assessed
Volume 33
Issue 4
Start page 507
End page 510
Total pages 4
Place of publication COLLINGWOOD
Publisher C S I R O PUBLICATIONS
Language eng
Abstract An ethylene permeation system was tested in a study of flower abscission of Verticordia nitens (Lindley) Endl. Various concentrations of ethylene in air were generated by passing air, at a flow rate of 2 L/min, through chambers containing various lengths of polyvinyl chloride (PVC) tubing pressurised (50 kPa) with ethylene. Ethylene permeating through lengths of PVC tubing of 1.5, 15, 150, and 1500 cm (8 mm internal diameter, 1.5 mm wall thickness) gave ethylene concentrations in the outflow airstreams of 0.12, 0.99, 7.8, and 100 muL/L, respectively. Increasing the ethylene pressure in 150-cm-long tubing linearly increased the permeation of ethylene (0.07 muL/L. kPa).
Keyword Air
Q-Index Code C1
Q-Index Status Provisional Code
Institutional Status Unknown

Document type: Journal Article
Sub-type: Article (original research)
Collection: ResearcherID Downloads - Archived
 
Versions
Version Filter Type
Citation counts: TR Web of Science Citation Count  Cited 0 times in Thomson Reuters Web of Science Article
Scopus Citation Count Cited 0 times in Scopus Article
Google Scholar Search Google Scholar
Created: Sat, 23 Feb 2013, 04:37:54 EST by System User