Quantification of the timing of continuous modulated muscle activity in a repetitive-movement task

Belavý, D. L., Wilson, S. J. and Richardson, C. A. (2006) Quantification of the timing of continuous modulated muscle activity in a repetitive-movement task. Physiological Measurement, 27 11: 1143-1150. doi:10.1088/0967-3334/27/11/007


Author Belavý, D. L.
Wilson, S. J.
Richardson, C. A.
Title Quantification of the timing of continuous modulated muscle activity in a repetitive-movement task
Journal name Physiological Measurement   Check publisher's open access policy
ISSN 0967-3334
1361-6579
Publication date 2006
Sub-type Article (original research)
DOI 10.1088/0967-3334/27/11/007
Volume 27
Issue 11
Start page 1143
End page 1150
Total pages 8
Editor M. H. Neuman
Place of publication Temple Back, Bristol, U.K.
Publisher Institute of Physics Publishing
Collection year 2006
Language eng
Subject C1
291599 Biomedical Engineering not elsewhere classified
730106 Cardiovascular system and diseases
Formatted abstract
The timing of muscle activity is commonly measured in studies of motor control. In repetitive-movement tasks, muscle activity may be continuous, and no defined onset or offset of activity may be measured. This does not imply that no timing of muscle activity occurs. Where activity is continuous, this timing will typically be exhibited by modulation of the amplitude of the signal in specific movement phases. The existence of this electromyographic (EMG) timing is dependent upon the existence of EMG amplitude modulation. This paper investigates this relationship in developing a quantification algorithm of EMG timing in a repetitive-movement task. A frequency domain quantification algorithm involving EMG linear-envelope generation is used. An EMG simulation algorithm is used to test this algorithm and determine the minimal amplitude-modulation threshold for timing detection. At five repetitive-movement speeds (25, 50, 75, 100 and 125 cycles of movement per minute), thresholds between 1.558 and 2.326 times maximal to minimal linear-envelope amplitude are required for reliability of timing detection. Analysis of variance indicates that the robustness of the quantification algorithm was not significantly affected by burst width (F = 3.69, p = 0.055) or the underling input timing parameter (F = 0.52, p = 0.992). The phase-lead/lag quantification algorithm represents a useful tool for the analysis motor control via EMG during repetitive-movement tasks.
© 2006 IOP Publishing Ltd
Keyword Surface Electromyography
Repetitive-movement
Motor Control
Onset
Phase-lead/lag
Biophysics
Engineering, Biomedical
Physiology
Activation
Diaphragm
Q-Index Code C1
Q-Index Status Provisional Code
Institutional Status UQ

 
Versions
Version Filter Type
Citation counts: TR Web of Science Citation Count  Cited 2 times in Thomson Reuters Web of Science Article | Citations
Scopus Citation Count Cited 2 times in Scopus Article | Citations
Google Scholar Search Google Scholar
Created: Wed, 15 Aug 2007, 09:08:18 EST