High-resolution differential-pressure indicator for the low-speed wind tunnel

Jacobs, P. A. (2014) High-resolution differential-pressure indicator for the low-speed wind tunnel. Mechanical Engineering Technical Report 2013/17, School of Mechanical and Mining Engineering, The University of Queensland.

Attached Files (Some files may be inaccessible until you login with your UQ eSpace credentials)
Name Description MIMEType Size Downloads
report_2013_17_hi_res_diff_p_indicator.pdf Full text (open access) application/pdf 2.34MB 63
Author Jacobs, P. A.
Title High-resolution differential-pressure indicator for the low-speed wind tunnel
School, Department or Centre School of Mechanical and Mining Engineering
Institution The University of Queensland
Open Access Status Other
Report Number 2013/17
Series Mechanical Engineering Technical Report
Publication date 2014-05-22
Start page 1
End page 13
Total pages 13
Publisher The University of Queensland
Language eng
Formatted Abstract/Summary
This report describes the hardware and firmware for a differential-pressure indicator for the low-speed wind tunnel. It is essentially a two-channel high-resolution voltmeter attached to a pair of Sensirion pressure sensors but, being built around a microcontroller running FlashForth, it is programmable.
Q-Index Status Provisional Code
Institutional Status UQ

Document type: Department Technical Report
Collection: School of Mechanical & Mining Engineering Publications
 
Versions
Version Filter Type
Citation counts: Google Scholar Search Google Scholar
Created: Thu, 22 May 2014, 19:22:13 EST by Peter Jacobs on behalf of School of Mechanical and Mining Engineering