Partial volume correction using reverse diffusion

Salvado, Olivier, Hillenbrand, Claudia and Wilson, David L. (2005). Partial volume correction using reverse diffusion. In: J. Michael Fitzpatrick and Joseph M. Reinhardt, Proceedings of SPIE: Medical Imaging 2005: Image processing. Medical Imaging 2005 Conference, San Diego, CA, United States, (625-633). 15-17 February 2005. doi:10.1117/12.596220

Attached Files (Some files may be inaccessible until you login with your UQ eSpace credentials)
Name Description MIMEType Size Downloads
UQ246083_OA.pdf Full text (open access) application/pdf 290.59KB 0

Author Salvado, Olivier
Hillenbrand, Claudia
Wilson, David L.
Title of paper Partial volume correction using reverse diffusion
Conference name Medical Imaging 2005 Conference
Conference location San Diego, CA, United States
Conference dates 15-17 February 2005
Proceedings title Proceedings of SPIE: Medical Imaging 2005: Image processing   Check publisher's open access policy
Journal name Medical Imaging 2005: Image Processing, Pt 1-3   Check publisher's open access policy
Place of Publication Bellingham, WA, United States
Publisher SPIE - International Society for Optical Engineering
Publication Year 2005
Sub-type Fully published paper
DOI 10.1117/12.596220
Open Access Status File (Publisher version)
ISBN 0-8194-5721-3
ISSN 0277-786X
Editor J. Michael Fitzpatrick
Joseph M. Reinhardt
Volume 5747
Start page 625
End page 633
Total pages 9
Language eng
Abstract/Summary Many medical images suffer from the partial volume effect where a boundary between two structures of interest falls in the middle of a voxel giving a signal value that is a mixture of the two. We propose a method to restore the ideal boundary by splitting a voxel into sub-voxels and reapportioning the signal into the sub-voxels. We designed this method to correct MRI 2D slice images where partial volume can be a considerable limitation. Each voxel is divided into four (or more) sub-voxels by nearest neighbor interpolation. The gray level of each sub-voxel is considered as "materials" able to move between sub-voxels but not between voxels. A partial differential equation is written to allow the material to flow towards the highest gradient direction, creating a "reverse" diffusion process. Flow is subject to constraints that tend to create step edges. Material is conserved in the process thereby conserving MR signal. The method proceeds until the flow decreases to a low value. To test the method, synthetic images were down-sampled to simulate the partial volume artifact and restored. Corrected images were remarkably closer both visually and quantitatively to the original images than those obtained from common interpolation methods: on simulated data mean square errors were 0.35, 1.09, and 1.24 for the proposed method, bicubic, and bilinear interpolation respectively. The method was relatively insensitive to noise. On MRI physical phantom and brain images, restored images processed with the new method were visually much closer to high-resolution counter-parts than those obtained with common interpolation methods.
Keyword (10) interpolation
Partial voluming
Q-Index Code E1
Q-Index Status Provisional Code
Institutional Status Non-UQ

Version Filter Type
Citation counts: TR Web of Science Citation Count  Cited 3 times in Thomson Reuters Web of Science Article | Citations
Scopus Citation Count Cited 3 times in Scopus Article | Citations
Google Scholar Search Google Scholar
Created: Mon, 22 Aug 2011, 18:47:25 EST by System User on behalf of School of Information Technol and Elec Engineering