Biomechanical characterization of a micro/macroporous polycaprolactone tissue integrating vascular graft

Wang, Yiwei, Lam, Jenny, Zhang, Bufa, Tomlins, Paul E., Li, Xiongwei, Alpar, Oya, Wertheim, David F., Jones, Allan S. and Coombes, Allan G. A. (2010) Biomechanical characterization of a micro/macroporous polycaprolactone tissue integrating vascular graft. Cardiovascular Engineering and Technology, 1 3: 202-215. doi:10.1007/s13239-010-0019-1


Author Wang, Yiwei
Lam, Jenny
Zhang, Bufa
Tomlins, Paul E.
Li, Xiongwei
Alpar, Oya
Wertheim, David F.
Jones, Allan S.
Coombes, Allan G. A.
Title Biomechanical characterization of a micro/macroporous polycaprolactone tissue integrating vascular graft
Journal name Cardiovascular Engineering and Technology   Check publisher's open access policy
ISSN 1869-408X
1869-4098
Publication date 2010-09
Sub-type Article (original research)
DOI 10.1007/s13239-010-0019-1
Volume 1
Issue 3
Start page 202
End page 215
Total pages 14
Place of publication New York, NY, United States
Publisher Springer New York LLC
Collection year 2011
Language eng
Subject 090301 Biomaterials
920118 Surgical Methods and Procedures
Abstract The objective of the present study was to characterize the short-term biomechanical properties of cast micro/macroporous poly(caprolactone) (PCL) tubes intended for application as tissue integrating blood vessel substitutes. Micro/macroporous PCL vascular grafts (5.5 mm internal diameter, 7.5 mm external diameter) with defined macropore structures were produced by rapidly cooling PCL solutions containing dispersed gelatin particles in dry ice, followed by solvent and gelatin extraction. A Bose-Enduratec BioDynamic chamber configured for cardiovascular applications was used to measure the diametrical stability (dilation) of tubular samples under hydrodynamic flow conditions at 37 °C. Microporous PCL tubes withstood the hydrodynamic stresses induced by short, 2-min duration flow rates up to 1000 mL/min, which resulted in estimated internal pressures in excess of arterial pressure (80–130 mmHg). Micro/macroporous PCL tubes having a maximum macroporosity of 23% accommodated the hydrodynamic stresses generated by short duration, flow rates up to 1000 mL/min, which resulted in estimated internal pressures similar to venous pressure (30 mmHg).The dilation of microporous PCL tubes under short, (5 min) pulsatile flow conditions (1 Hz) increased from 10 to 100 μm with increasing mean flow rate from 50 to 500 mL/min. Both microporous and macroporous tubes exhibited a burst strength higher than 900 mmHg under hydrostatic fluid pressure, which is in excess of arterial pressure (80–130 mmHg) by a factor of approximately 7. Quantitative analysis of the macropore structure was performed using micro-computed tomography for correlation with mechanical properties and cell growth rates. Mouse fibroblasts efficiently colonized the external surface of macroporous PCL materials over 8 days in cell culture and cell numbers were higher by a factor of two compared with microporous PCL. These findings demonstrate that micro/macroporous PCL tubes designed for vascular tissue engineering can accommodate the hydrodynamic stresses generated by short duration, simulated blood flow conditions and exhibit good potential for integration with host tissue. © 2010 Biomedical Engineering Society.
Keyword Polycaprolactone
Porous-walled tubes
Scaffolds
Vascular grafts
Biomechanical properties
X-ray microcomputed tomography μCT
Q-Index Code C1
Q-Index Status Confirmed Code
Institutional Status UQ

Document type: Journal Article
Sub-type: Article (original research)
Collections: Official 2011 Collection
School of Pharmacy Publications
 
Versions
Version Filter Type
Citation counts: Scopus Citation Count Cited 1 times in Scopus Article | Citations
Google Scholar Search Google Scholar