A Comparative study of voltage stability for long distance HVAC and HVDC interconnections

Nguyen, Mai H., Saha, Tapan K. and Eghbal, Mehdi (2010). A Comparative study of voltage stability for long distance HVAC and HVDC interconnections. In: , IEEE PES General Meeting. 2010 IEEE Power and Energy Society General Meeting, Minneapolis, Minnesota, USA, (1-8). 25-29 July 2010.

Attached Files (Some files may be inaccessible until you login with your UQ eSpace credentials)
Name Description MIMEType Size Downloads
UQ218222_Combined.pdf HERDC combined - not publicly available application/pdf 1.41MB 137

Author Nguyen, Mai H.
Saha, Tapan K.
Eghbal, Mehdi
Title of paper A Comparative study of voltage stability for long distance HVAC and HVDC interconnections
Conference name 2010 IEEE Power and Energy Society General Meeting
Conference location Minneapolis, Minnesota, USA
Conference dates 25-29 July 2010
Proceedings title IEEE PES General Meeting
Journal name Ieee Power and Energy Society General Meeting 2010
Place of Publication Piscataway, N.J., U.S.A.
Publisher IEEE
Publication Year 2010
Sub-type Fully published paper
DOI 10.1109/PES.2010.5589456
ISBN 9781424483570
9781424465491
ISSN 1944-9925
Issue Article number 5589456
Start page 1
End page 8
Total pages 8
Collection year 2011
Language eng
Formatted Abstract/Summary This paper presents a comparative study of voltage stability indices for three different long transmission technologies. High Voltage AC (HVAC), hybrid High Voltage DC (HVDC) and bipolar HVDC lines are compared in terms of voltage stability and point of collapse. Each scenario is analyzed with different lengths of transmission lines and in different contingency conditions. The impacts of HVDC control modes and parameters on interconnection voltage stability are also examined. Simulations are carried out on a simplified Australian power system with CIGRE HVDC models using the Power Factory software package.
Subjects 090608 Renewable Power and Energy Systems Engineering (excl. Solar Cells)
850603 Energy Systems Analysis
E1
Keyword HVAC
HVDC systems
long transmission
Point of Collapse (PoC)
Voltage stability
Q-Index Code E1
Q-Index Status Confirmed Code
Institutional Status UQ
Additional Notes Presented at T&D Poster Session

Document type: Conference Paper
Collections: School of Mechanical & Mining Engineering Publications
Non HERDC
 
Versions
Version Filter Type
Citation counts: TR Web of Science Citation Count  Cited 0 times in Thomson Reuters Web of Science Article
Scopus Citation Count Cited 0 times in Scopus Article
Google Scholar Search Google Scholar
Access Statistics: 303 Abstract Views, 138 File Downloads  -  Detailed Statistics
Created: Mon, 11 Oct 2010, 14:22:35 EST by Dr Mehdi Eghbal on behalf of School of Mechanical and Mining Engineering