Infection control practices among hospital health and support workers in Hong Kong

Chau, J. P. C., Thompson, D. R., Lee, D. T. F. and Twinn, S. (2010) Infection control practices among hospital health and support workers in Hong Kong. Journal of Hospital Infection, 75 4: 299-303. doi:10.1016/j.jhin.2009.10.014

Attached Files (Some files may be inaccessible until you login with your UQ eSpace credentials)
Name Description MIMEType Size Downloads
David_R_Thompson._Support_Evidence.pdf HERDC evidence - not publicly available application/pdf 192.66KB 1

Author Chau, J. P. C.
Thompson, D. R.
Lee, D. T. F.
Twinn, S.
Title Infection control practices among hospital health and support workers in Hong Kong
Journal name Journal of Hospital Infection   Check publisher's open access policy
ISSN 0195-6701
Publication date 2010-08
Sub-type Article (original research)
DOI 10.1016/j.jhin.2009.10.014
Volume 75
Issue 4
Start page 299
End page 303
Total pages 5
Place of publication London, United Kingdom
Publisher W.B. Saunders
Collection year 2011
Language eng
Subject C1
920210 Nursing
111705 Environmental and Occupational Health and Safety
Abstract A report by the Hong Kong government noted that hospital infection control standards were inadequate, requiring audit, development and implementation. In addition, hospital staff needed training in infection control measures. We investigated infection control practices among 162 hospital health workers (109 nurses, 45 doctors and 8 therapists) and 44 support workers in one acute hospital and two rehabilitation hospitals using a non-blinded, observational design. We examined compliance with isolation precautions and infection control guidelines, including proper wearing of a mask, goggles/face shield, or gown; handling patient care equipment, linen, and laundry; routine and terminal cleaning; and terminal cleaning of an isolation room. One major breakdown in compliance was use of sleeveless disposable plastic aprons instead of long-sleeved gowns during procedures likely to generate splashes or sprays of blood and body fluids. In more than half of the observed episodes, participants failed to disinfect medical devices, such as stethoscopes, before re-use. Thorough cleansing of commodes between patients was also lacking. Overall compliance with local and international infection control guidelines was satisfactory, but several aspects required improvement. © 2009 The Hospital Infection Society.
Keyword Clinical audit
Infection control
Q-Index Code C1
Q-Index Status Confirmed Code
Institutional Status UQ

Document type: Journal Article
Sub-type: Article (original research)
Collections: Official 2011 Collection
School of Nursing, Midwifery and Social Work Publications
Version Filter Type
Citation counts: TR Web of Science Citation Count  Cited 5 times in Thomson Reuters Web of Science Article | Citations
Scopus Citation Count Cited 6 times in Scopus Article | Citations
Google Scholar Search Google Scholar
Created: Mon, 09 Aug 2010, 09:13:24 EST by Vicki Percival on behalf of School of Nursing, Midwifery and Social Work